OCT-1000 Ophthalmic OCT Machine

Modelo: OCT-1000

  • 12 mm × 9 mm Wide Scan Range: Covers the macula and optic disc with accurate quantitative results.
  • Fully Automatic Operation: Automatically captures, aligns, and scans for quick exams.
  • AI Image Analysis: Detects 16 major fundus lesions to support diagnosis.
  • Cloud-Based Management: Shares data instantly for remote consultations.
  • Voice Guidance: Provides clear, step-by-step instructions.

Explorar detalhes

The OCT-1000 OCT Tomography Machine offers fully automatic operation with a 12 mm × 9 mm wide-field scan covering both the macula and optic disc, providing fast, accurate, and quantitative analysis—including choroidal and central macular thickness—for early retinal disease detection and efficient clinical diagnostics.It allows eye care professionals to detect structural changes that are not visible through standard examination methods.

OCT-1000 be used for:

  • Ophthalmology clinics
  • Hospitals
  • Specialized eye care centers
  • Advanced optical practices
OCT-1000 partial view image

Patient Fixation Frame

The OCT-1000 prioritizes automation, precision, and patient comfort, which forms the foundational hardware for its "fully automated operation," "large field of view scanning," and "AI-assisted diagnosis" functions.

OCT-1000 partial view image

Base Unit

It supports connectivity with various external devices, facilitating data export, system maintenance, and integration into a wider range of healthcare information networks.

OCT-1000 structure image

OCT-1000 Optical Coherence Tomography Technical Sheet

ParâmetroBigVision1000T1000S1000M
TypeSpectral domain OCT (SD-OCT)Spectral domain OCT (SD-OCT)Spectral domain OCT (SD-OCT)Spectral domain OCT (SD-OCT)
Optical energy (at cornea)≤750μW≤750μW≤750μW≤750μW
Measurement characteristicsAxial resolution: 5 μm.
Transverse resolution: 20μm.
Axial resolution: 5 μm.
Transverse resolution: 20μm.
Axial resolution: 5 μm.
Transverse resolution: 20μm.
Axial resolution: 5 μm.
Transverse resolution: 20μm.
Scanning characteristicsMaximum a scanning speed: ≥ 20000 times/second
Scanning depth: 2.3mm
Maximum scanning range: 12mm*9mm
Maximum A scanning speed: ≥ 80,000 times/second
Scanning depth: 2.3mm
Maximum scanning range: 12mm*9mm
Maximum A scanning speed: ≥ 55000 times/second
Scanning depth: 2.3m
Maximum scanning range: 10mm*9mm
Maximum A scanning speed: ≥ 55000 times/second
Scanning depth: 2.3mm
Maximum scanning range: 12mm*9mm
Light source characteristicsCentral wavelength: 840nm
Optical power: ≤ 750μW.
Refractive compensation range: -20D~+25D.
Central wavelength: 840nm
Optical power: ≤ 750μW.
Refractive compensation range: -20D~+25D.
Central wavelength: 840nm
Optical power: ≤ 750 μW.
Refractive Compensation range: -20D~+25D.
Central wavelength : 840nm
Optical power: ≤ 750μW.
Refractive Compensation range: -20 D~+25D.
Scanning modeFive modes:
Large field of vision: high-definition straight line, six lines of radiation, local area: macula, optic disc.
Seven modes:
Large field of vision: high-definition straight line, six lines of radiation, area: Local: macula and optic disc. Anterior segment: high-definition straight line, six lines of radiation.
Seven modes:
Large field of vision: high-definition straight line, six lines of radiation, area: Local: macula and optic disc. Anterior segment: high-definition straight line, six lines of radiation.
Seven modes:
Large field of vision: high-definition straight line, six lines of radiation, area: Local: macula and optic disc. Anterior segment: high-definition straight line, six lines of radiation.
Scanning range12mm*9mm
Complete the image acquisition of macular+optic disc at one time.
12mm*9mm
Complete the image acquisition of macular+optic disc at one time.
12mm*9mm
Complete the Image acquisition of macular+optic disc at one time.
10mm*9mm
Complete the Image acquisition of macular+opti c disc at one time.
Single-line scanning length12mm (6mm in anterior segment)
Anterior chamber Corneal topography
12mm (6mm in anterior segment)
Anterior chamber Corneal topography
12mm (6mm In anterior segment)
Anterior chamber Corneal topography
12mm (6mm In anterior segment)
Anterio r chamber Corneal topography
Minimum pupil diameter2mm2mm2mm2mm
Pupil automatic positioning✓✓✓✓
Pupil automatic compensation✓✓✓✓
Fundus imageAll-pixel imaging technology based on high scanning speedAll-pixel imaging technology based on high scanning speedAll-pixel imaging technology Based on high scanning speedAll-pixel imaging technology based on high scanning speed
Focusingfully automaticfully automaticfully automaticfully automatic
Integrated artificial intelligenceAssisted diagnosis of 25 major ophthalmic diseases, accurate identification, segmentation and diagnosis.Assisted diagnosis of 25 major ophthalmic diseases, accurate identification, segmentation and diagnosis.Assisted diagnosis of 25 major ophthalmic diseases, accurate identification, segmentation and diagnosis.Assisted diagnosis of 25 major ophthalmic diseases, accurate identification, segmentation and diagnosis.
DICOM interface function✓✓✓✓
Mode of operationFully automatic and manual operationFully automatic and manual operationFully automatic and manual operationFully automatic and Manual operation

Vídeo

Serviços de confiança:

1. Video chat to check OCT-1000 OCT Tomography Machine.

2. Apoio técnico e formação online gratuitos.

3. Apoio gratuito à instalação online.

4. Garantia de qualidade de 1 a 3 anos.

5. Apoio pós-venda vitalício.

6. A maioria dos produtos possui certificação CE e ISO 13485.

7. Personalização livre da tensão de entrada e do conector para máquinas elétricas. 

8. Envio rápido para todo o mundo, com entrega em 5 a 10 dias úteis na maioria dos países. 

9. É aceitável o pagamento antecipado parcial antes do envio.

10. Podem ser oferecidos aos distribuidores produtos a preço com desconto, sem marca ou personalizados.

Críticas - E quanto a...

OCT-1000 Ophthalmic OCT Machine

FAQs About OCT-1000 ocular coherence tomography machine

Exibição de certificados

FDA
ISO 9001
ISO 13485
equipamento para optometristas CE
CE

Oficina de Produção

Workshop
torno
Centro de Processamento
Tinta em spray
Corte a laser
Soco

Envio e Carga

Pacote
inventário
A carregar

Soluções para os cuidados oftalmológicos a nível mundial

A Shanghai LINKEYE presta serviços a profissionais de saúde ocular de todo o mundo, incluindo distribuidores, hospitais, clínicas oftalmológicas, óticas, projetos governamentais, parceiros OEM/ODM e consumidores que procuram soluções fiáveis para o cuidado da visão.

Distribuidores e grossistas

Fornecimento estável, preços competitivos e um forte apoio do mercado aos parceiros de distribuição locais.

Hospitais e Clínicas Oftalmológicas

Hospitais e clínicas oftalmológicas

Fornecimento estável, preços competitivos e um forte apoio do mercado aos parceiros de distribuição locais.

Óticas e cadeias de lojas

Soluções eficientes para salas de refração, óticas de retalho e cadeias de lojas.

Projetos governamentais e médicos

Projetos governamentais e médicos

Apoio técnico fiável em matéria de equipamento para concursos públicos no setor da saúde e projetos médicos internacionais.

Consumidores e Parceiros

Consumidores e Parceiros

Profissionais da área da oftalmologia e utilizadores particulares que procuram exames de rastreio da visão e soluções para os cuidados oftalmológicos.

Contacte-nos

Basta preencher o formulário abaixo da melhor forma possível e, depois, deixar o resto connosco.

Obtenha uma resposta rápida

Deixar uma mensagem

Tem alguma dúvida? Envie-nos um e-mail ou ligue-nos a qualquer hora, estaremos ao seu dispor.

Sala 135, 1101 Huyi Highway, vila de Nanxiang, distrito de Jiading, Xangai, China.

É com grande prazer que recebemos o seu pedido de informação e estaremos sempre à sua disposição para lhe prestar todo o apoio necessário. “Agregar valor aos profissionais de cuidados oftalmológicos em todo o mundo” é um objetivo constante da Shanghai LINKEYE Instrument. Contacte-nos a qualquer momento.

Página inicial Página inicial Produto Produto E-mail E-mail Conversa Conversa Mensagem Mensagem