BIO-1100 Projection type Humphrey Visual Field Analyzer

Model: BIO-1100

  • Projection-type dynamic perimeter with precise visual field mapping.
  • Multiple testing modes and customizable test patterns.
  • Blue-yellow (SWAP) mode for early glaucoma detection.
  • Professional software for patient management and report generation.
  • Fast, accurate, and user-friendly operation for clinical use.

BIO-1100 is a projection-type dynamic (kinetic) visual field analyzer mainly used for ophthalmologists or optometrists to monitor or detect glaucoma progression.

Explore Details

BIO-1100 is a projection type humphrey visual field analyzer machine for visual field defects examination, especially for glaucoma test. It has much more test spots than static auto perimeter, so it provides more accurate results.

This BIO-1100 visual field testing machine has professional software. There are several testing strategies (threshold, screen, special, custom, dynamic and custom dynamic) and testing patterns to choose for fast examinations. It has blue-yellow examination mode, and you can setup white or yellow background light. Ophthalmologists can easily manage patient information and print detailed test reports.

Features:

1. Conform to Goldman international standard.

2. Halogen projection system: stimulation light source is from wide band visible spectrum, fully meet colored cone cell stimulation.

3. Accurate and rich database of normal population of all age groups, helps early diagnosis of minor visual field defects.

4. GHT glaucoma semi vision analysis, make glaucoma diagnosis easier.

5. Upgraded GPA glaucoma progression analysis helps obviously monitor slight glaucoma development.

6. Standard SWAP blue-yellow visual field examination, effective for earlier visual field defects detection.

7. Scientific and intelligent interactive inspection strategies ensures fast measurement, 30 degree range visual field inspection only takes 3 minutes.

8. Simple and user-friendly software makes it easy to learn operation of the machine.

Early Detection of Subtle Visual Defects

Early Detection of Subtle Visual Defects

The BIO-1100 uses a detailed, age-stratified normal population database to identify minor visual field changes that may be overlooked by conventional perimeters, enabling earlier and more accurate diagnosis of visual disorders.

Same function as Zeiss Humphrey 860

Comparable to Zeiss Humphrey 860

The BIO-1100 offers similar advanced visual field testing functions as the Zeiss Humphrey 860, including high-density projection testing, multiple strategies and patterns, SWAP blue-yellow mode, and comprehensive glaucoma analysis (GHT & GPA). It provides accurate, early detection of subtle visual field defects, fast examination, and user-friendly software for efficient patient management, making it a cost-effective alternative for professional ophthalmic clinics.

Display of each module of BM-6000

Specifications:

Testing scope90°
Testing distance30 cm
Background lightwhite31.5asb, yellow315asb
Visual target 0.08 asb -10000 asb (0-51DB)
Target sizeGoldmann I , II, Ⅲ, IV, V
Visual target stimulation time200 ms
Visual target interval time Standard and custom
Threshold policy Macula, 10-2, 24-2, 30-2, 60-4, nasal side
Upper threshold policyC-40, C-64, C-76, FF-81, FF-120, FF-135……
Special detection strategy Esterman monocular, Esterman binocular, upper 36°screening, blind point testing
Yellow- blue testing Standard 440nm blue V visual target + 315asb OG530  yellow background brightness
Visual targetRed, blue
Dynamic policyStandard dynamic, blind dynamic, dark spot dynamic, straight line dynamic
Custom policyStatic custom dynamic custom 
Pupil size measurementAuto
Fixation monitoring Physiological blind spot monitoring, eye position monitoring, eye position moving alarm, eye tracking curve
Environment light testingAuto
Analysis softwareReliability analysis , single report, triple report, GHT glaucoma semi vision report, GPA glaucoma developing analysis, VFI analysis, Blue-yellow analysis
System   Win7 above

 

Video

Trusted Services:

1. Video chat to check BIO-1100 projection type humphrey visual field analyzer.

2. Free online technical support and training.

3. Free online installation support.

4. 1-3 Years quality warranty.

5. Lifetime after sales support.

6. Most products are CE and ISO 13485 certificated.

7. Free input voltage and plug customization for electrical machines. 

8. Fast worldwide shipping, 5-10 working days delivery for most countries. 

9. Partial prepayment is acceptable before shipping.

10. Discount price, non-branded or customized products can be offered for distributors.

Reviews - What About

BIO-1100 Projection type Humphrey Visual Field Analyzer

Certificate Display

FDA
ISO9001
ISO13485
optometrists equipment CE
CE

Production Workshop

Workshop
lathe
Processing Center
Spray Paint
Laser Cutting
Punching

Shipping & Loading

Pack
inventory
Loading

Contact With Us

Simply fill out the form below as much as you can, then leave the rest to us.

Get quick response

Leave Message

Question? Email us or give us a call at anytime, we will be at your serivce.

Room 135, 1101 Huyi Highway,Nanxiang Town,Jiading District,Shanghai, China.

It’s our pleasure to receive your enquiry, and we will provide full support always. “Bringing Value To Eye Care Practitioners Worldwide” is a consistent goal of Shanghai LINK Instrument. Contact us at any time.

Home Home Product Product Email Email Chat Chat Message Message